Oxygen:

Meter % Drop to PPM: 20.9% – Actual Reading% x 5 x 10,000 = PPM Drop

Predicted O2 Reading: 1300 Rule PPM for Known Chemical ÷ 50,000 = Predicted drop

Subtract Predicted Drop from 20.9% = Predicted % O2 Meter Reading